Test 34C - EIC Switch Operation

NOTE: For connector terminal identification, see CONNECTOR  IDENTIFICATION. For wiring diagram, see WIRING DIAGRAMS  . Perform TEST VER-1 after each repair.
CAUTION: Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
  1. Use DRB to monitor EIC TRIP switch status. If DRB displays TRIP ODO : CLOSED, replace instrument cluster. If DRB does not display TRIP ODO : CLOSED, go to next step.
  2. Press TRIP button on instrument cluster. If DRB does not display TRIP ODO : CLOSED, replace instrument cluster. If DRB displays TRIP ODO: CLOSED, go to next step.
  3. Use DRB to read EIC US/M switch status. If DRB displays US/METRIC : CLOSED, replace instrument cluster. If DRB does not display US/METRIC : CLOSED, go to next step.
  4. Press US/M button on instrument cluster. If DRB does not display US/METRIC : CLOSED, replace instrument cluster. If DRB displays US/METRIC : CLOSED, go to next step.
  5. Use DRB to read EIC RESET switch status. If DRB displays TRIP RESET : CLOSED, replace instrument cluster. If DRB does not display TRIP RESET : CLOSED, go to next step.