FixVault

Test 7E - Short To Battery

NOTE: For connector terminal identification, see CONNECTOR  IDENTIFICATION. For wiring diagram, see WIRING DIAGRAMS  . Perform TEST VER-1 after each repair.

Using DRB in ohmmeter mode, check resistance of instrument cluster connector terminal No. 7 (Black/Light Green wire). If resistance is more than 5 ohms, repair open in Black/Light Green wire. If resistance is less than 5 ohms, replace MIC or EIC.