FixVault

Test 58B - Instrument Cluster Printed Circuit Board

NOTE: For connector terminal identification, see CONNECTOR IDENTIFICATION  . For wiring diagrams, see appropriate article in ENGINE PERFORMANCE:
  1. Using scan tool, stop actuation test. Turn ignition off. Remove and inspect inoperative lamp. Replace lamp If necessary. If lamp is okay, go to next step.
  2. Inspect instrument cluster printed circuit board. Replace printed circuit board if necessary. If printed circuit board is okay, repair or replace instrument cluster. See INSTRUMENT PANELS article in ACCESSORIES & EQUIPMENT.