Seat Belt Switch Circuit Short To Ground

NOTE: Perform INSTRUMENT CLUSTER TEST 1A  before proceeding with this test. For connector terminal identification and wiring diagrams, see BODY CONTROL COMPUTER - INTRODUCTION. Perform VERIFICATION TEST: VER-2A  after each repair.

While observing seat belt indicator, cycle key to OFF then ON position. If seat belt indicator is illuminated for 10 seconds, go to CHIME TEST 4B . If seat belt indicator is not illuminated for 10 seconds, replace instrument cluster.