FixVault

DTC P1195: Slow Upstream O2 Sensor During Catalyst Monitor: Notes

NOTE: After making repairs for DTC P1195, perform TEST VER-5A: ROAD TEST FOR OBD II VERIFICATION  .
NOTE: O2 sensor 1/1 is upstream oxygen sensor, located in front of catalytic converter. O2 sensor 1/2 is downstream oxygen sensor, located behind of catalytic converter.