All Doors (Except Driver) Fail To Lock
Turn ignition off. Disconnect Remote Keyless Entry (RKE) module connector, located under pad in center of instrument panel. Using an ohmmeter, check resistance between RKE module connector terminal No. 4, door lock driver circuit (Orange/Black wire) and ground. See Figure. If resistance is less than 1000 ohms, repair Orange/Black wire for short to ground. If resistance is 1000 ohms or more, replace RKE module. See REMOTE KEYLESS ENTRY MODULE under REMOVAL & INSTALLATION. After repairs, perform BODY VERIFICATION TEST under VERIFICATION TESTS.