Standard Procedure - Draining Fuel Tank
- Release fuel system pressure, refer to STANDARD PROCEDURE - FUEL SYSTEM PRESSURE RELEASE PROCEDURE .
- Insert a 1/4 inch siphon (max. O. D. 5/16) hose from a portable fuel siphoning tank through the fuel filler neck opening into the fuel tank. Hose most have a 30 degree angle cut on the end to bypass the check valve in the end of the filler neck. Refer to the siphoning tank's Manufacturing Instructions.
- Drain fuel from fuel tank into siphoning tank.