FixVault

Sensor Testing

  1. Turn the ignition switch to the OFF position. Disconnect and isolate the battery negative cable (Fig 1 ). Disconnect the ambient temperature sensor wire harness connector.
    Fig 1: Removing Battery Negative Cable
    G03527066Courtesy of DAIMLERCHRYSLER CORP.
  2. Measure the resistance of the ambient temperature sensor. At room temperature (approx. 68°F), the sensor resistance should be between 9--11 Kilo-hms (9000--11000 ohms). The sensor resistance should read between these two values. If OK, refer to SENSOR CIRCUIT TESTING  below. If not OK, replace the faulty ambient temperature sensor.