FixVault

Structural Cover: Installation

CAUTION: The collar must be tightened using this service procedure, as damage to collar and/or oil pan may occur.
  1. Install structural collar (Figure ) using the following tightening sequence:
    • Loosely install the collar to oil pan bolts.
    • Loosely install the collar to transmission bolts.
    • Initial torque bolts to 27 N.m (20 ft. lbs.).
    • Final torque bolts to 55 N.m (40 ft. lbs.).
  2. Lower vehicle.