Charging System: Generator: Removal: 2.4L

  1. Release hood latch and open hood.
  2. Disconnect battery negative cable.
  3. Disconnect the Inlet Air Temperature sensor.
  4. Remove the Air Box, refer to appropriate ENGINE - MECHANICAL article for more information.
  5. Remove the EVAP Purge solenoid from its bracket and reposition.
  6. Disconnect the push-in field wire connector from back of generator.
  7. Remove nut holding B+ wire terminal to back of generator.
  8. Separate B+ terminal from generator.
  9. Remove accessory drive belt, refer to COOLING for proper procedures.
  10. Remove the generator.