FixVault

Duct-Instrument Panel: Removal

WARNING: This page is about a different car, the 2006 Dodge Magnum, 2006 Dodge Charger, and 2006 Chrysler 300. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: On vehicles equipped with airbags, disable the airbag system before attempting any steering wheel, steering column, or instrument panel component diagnosis or service. Disconnect and isolate the battery negative (ground) cable, then wait two minutes for the airbag system capacitor to discharge before performing further diagnosis or service. This is the only sure way to disable the airbag system. Failure to take the proper precautions could result in accidental airbag deployment and possible personal injury or death.
NOTE: Take the proper precautions to protect the front face of the instrument panel from cosmetic damage.
Fig 1: Remove/Install Instrument Panel Ducts
GC0013949Courtesy of DAIMLERCHRYSLER CORP.
NOTE: LHD model shown. RHD model similar.
  1. Remove the instrument panel and place it on a workbench (Refer to BODY/INSTRUMENT PANEL/INSTRUMENT PANEL ASSEMBLY - REMOVAL) .
  2. Remove the screw that secures the instrument panel top pad (1) to the reinforcement bracket (2).
  3. Remove the four screws that secure the driver side instrument panel duct and demister duct assembly (3) to the instrument panel and remove the duct assembly.
  4. Remove the four screws that secure the passenger side instrument panel duct and demister duct assembly (4) to the instrument panel and remove the duct assembly.