FixVault

Generator - 3.5L

Fig 1: Identifying Cable Connections
GC0058870Courtesy of CHRYSLER LLC
  1. Disconnect negative battery cable.
  2. Remove engine cover.
  3. Disconnect battery cable from generator.
  4. Disconnect electrical connector from generator.
    Fig 2: Identifying Generator Bolts
    GC0058871Courtesy of CHRYSLER LLC
  5. Remove accessory drive belt, refer to REMOVAL .
  6. Remove two mounting bolts.
  7. Remove generator.