FixVault

Programming The RF-Hub

NOTE:

If a BCM is also going to be replaced at this time, check the "RF-HUB, BCM, FOBIK REPLACEMENT AND PROGRAMMING ORDER GUIDE" before proceeding. Refer to STANDARD PROCEDURE .

NOTE:

Do not put a laptop or any wireless device (cell phones, audio devices etc.) near the top of the center console (the RKE antenna is located below the center console).

NOTE:

After the RFHM is replaced and programed with a new Unit, review the door handle configuration in order to enable or disable diagnostics for the passenger door handle based on the vehicle configuration. If the vehicle is NOT equipped with passenger door handle, RFHM configuration needs to be checked to make sure diagnostics are disabled accordingly using the proper service routines in the RFHM.

  1. After the RF-Hub has been replaced with new unit, connect the diagnostic scan tool to the Data Link Connector (DLC).
  2. Turn the ignition ON
  3. Navigate to the RF-Hub (RFH) in the "Vehicle View" of the diagnostic scan tool.
  4. Turn the ignition OFF
  5. Put all the FOBiKs used in this vehicle on the front seat away from the console.
  6. With the scan tool select: "Program ignition FOBIKs" in the Miscellaneous Functions menu and follow the instructions on the screen.
    NOTE:

    When programming a FOBIK, have it in your hand resting on the console.

    NOTE:

    When you are instructed to "Press the Unlock button" it is important that you do not hold the button. Press it One time quickly.

  7. After all the FOBIKs have been programmed, turn the ignition on and with the scan tool select "BCM".
  8. Select "Misc. Function" and perform the "PROXI Configuration Alignment" routine.
  9. With the scan tool select "RF-Hub" and perform the "RF-HUB Replace" routine.
  10. Update the Front and Rear Axle Normal Tire Pressure Values.
  11. Program the Tire Sensor IDs.
  12. Turn the ignition to the OFF position, wait 30 seconds, then cycle the ignition back to the ON/RUN position.
  13. Check for any active RF-Hub DTCs. If any are present, refer to the DTC INDEX article and perform the appropriate procedure.
  14. Turn the ignition off and check each FOBiK for proper operation.
  15. Finish the installation procedure (if necessary). Refer to MODULE, RADIO FREQUENCY (RF HUB), INSTALLATION .
  16. Perform the BODY VERIFICATION TEST. Refer to STANDARD PROCEDURE .