FixVault

Cluster Lens

WARNING: This page is about a different car, the 2015 Chrysler 200. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Gauge Needle & Zero Position
GC0162680Courtesy of CHRYSLER GROUP, LLC
  1. Using the procedure within the diagnostic scan tool, IPC Service Mode  , the gauge needles (1) must be moved from the zero position (2) to the service position.
    NOTE:

    The service position for the tachometer needle should be at 250 RPM, and the speedometer needle should be at 5 MPH, failure to perform this procedure could cause damage to the Instrument Panel Cluster (IPC).

  2. Remove the IPC. Refer to REMOVAL .
    Fig 2: IPC, Lens Unit & Clips
    GC0162564Courtesy of CHRYSLER GROUP, LLC
  3. Working around the perimeter of the IPC (3), release the clips (1) that secure the instrument cluster mask and lens unit (2) to the housing and remove the mask and lens.