Open Loop
When engine is first started and it is above 400 rpm, system goes into "open loop" operation. In "open loop," PCM/ECM ignores signal from O2S 1 and calculates air/fuel ratio based on inputs from ECT and MAP sensors. The sensor stays in "open loop" until following conditions are met:
- The O2S 1 sensor has a varying voltage output, showing that it is hot enough to operate properly.
- The ECT sensor is above a specified temperature.
- A specific amount of time has elapsed after starting engine.