Test 11E - Bus Short To Battery

NOTE: For connector terminal identification see CONNECTOR IDENTIFICATION  . For wiring diagrams, see WIRING DIAGRAMS  . Perform VERIFICATION TEST VER-1A  after each repair.
CAUTION: Always turn ignition off prior to disconnecting any module connector.

Turn ignition off. Using external ohmmeter, measure resistance between ground and instrument cluster 13-pin connector terminal No. 7 (Black/Light Green wire). If resistance is 5 ohms or more, repair open Black/Light Green wire circuit. If resistance is less than 5 ohms, replace instrument cluster.