The starter feed circuit test (voltage drop method) will determine if there is excessive resistance in high-amperage feed circuit. For complete starter wiring circuit diagrams, see WIRING DIAGRAMS  .

When performing these tests, it is important to remember that voltage drop is giving an indication of resistance between two points at which voltmeter probes are attached.

Example:  When testing resistance of positive battery cable, touch voltmeter leads to positive battery cable clamp and cable connector at starter solenoid. If you probe positive battery terminal post and cable connector at starter solenoid, you are reading combined voltage drop in positive battery cable clamp-to-terminal post connection and positive battery cable.

The following operation will require a voltmeter accurate to 1/10 (0.10) volt. Before performing tests, be certain that following procedures are accomplished:

  1. Connect positive lead of voltmeter (1) to negative battery cable terminal post. Connect negative lead of voltmeter to negative battery cable clamp. Rotate and hold ignition switch in Start position. Observe voltmeter (1). If voltage is detected, correct poor contact between cable clamp and terminal post. See Fig 1 .
    NOTE: Certain diesel equipped models use dual batteries. If equipped with dual battery system, procedure must be performed twice, once for each battery.
    Fig 1: Testing Battery Negative Terminal Voltage Drop
    G00309757Courtesy of DAIMLERCHRYSLER CORP.
  2. Connect positive lead of voltmeter (1) to positive battery terminal post. Connect negative lead of voltmeter to battery positive cable clamp. Rotate and hold ignition switch in Start position. Observe voltmeter (1). If voltage is detected, correct poor contact between cable clamp and terminal post. See Fig 2 .
    NOTE: Certain diesel equipped models use dual batteries. If equipped with dual battery system, this procedure must be performed twice, once for each battery.
    Fig 2: Testing Battery Positive Terminal Voltage Drop
    G00309761Courtesy of DAIMLERCHRYSLER CORP.
  3. Connect voltmeter (2) to measure between battery positive terminal post and starter solenoid battery terminal stud (3). Rotate and hold ignition switch in Start position. Observe voltmeter. If reading is above 0.2 volt, clean and tighten battery cable connection at solenoid. Repeat test. If reading is still above 0.2 volt, replace faulty positive battery cable.
    NOTE: Certain diesel equipped models use dual batteries. If equipped with dual battery system, this procedure must be performed on driver side battery only.
    Fig 3: Testing Battery Positive Cable Connection
    G00312507Courtesy of DAIMLERCHRYSLER CORP.
  4. Connect voltmeter (1) to measure between negative battery terminal post and a good clean ground on engine block (3). Rotate and hold ignition switch in Start position. Observe voltmeter. If reading is above 0.2 volt, clean and tighten negative battery cable attachment on engine block. Repeat test. If reading is still above 0.2 volt, replace faulty negative battery cable. See Fig 4 .
    NOTE: Certain diesel equipped models use dual batteries. If equipped with dual battery system, this procedure must be performed twice, once for each battery.
    Fig 4: Testing Battery Ground Cable Connection
    G00312511Courtesy of DAIMLERCHRYSLER CORP.
  5. Connect positive lead of voltmeter (3) to starter housing (1). Connect negative lead of voltmeter to negative battery terminal post. Rotate and hold ignition switch in Start position. Observe voltmeter. If reading is above 0.2 volt, correct poor starter to engine block ground contact.
    NOTE: Certain diesel equipped models use dual batteries. If equipped with dual battery system, this procedure must be performed on driver side battery only.
  6. If equipped with dual battery system (certain diesel equipped models), connect positive lead of voltmeter to positive battery cable clamp on battery located on left side of vehicle. Connect negative lead of voltmeter to positive battery terminal post on battery located on right side of vehicle. Rotate and hold ignition switch in Start position. Observe voltmeter. If reading is above 0.2 volt, clean and tighten battery cables at both batteries. Repeat test. If reading is still above 0.2 volt, replace faulty positive battery cable. See Fig 5 .
Fig 5: Testing With Voltmeter
G00312515Courtesy of DAIMLERCHRYSLER CORP.

If resistance tests detect no feed circuit problems, see STARTER MOTOR  in the TESTING section.