FixVault

Standard Procedure - Quick-Connect Fittings: Removal

When disconnecting a quick-connect fitting, the retainer will remain on the fuel tube nipple.

WARNING: RELEASE FUEL SYSTEM PRESSURE BEFORE DISCONNECTING A QUICK-CONNECT FITTINGS. REFER TO THE FUEL PRESSURE RELEASE PROCEDURE . THIS MAY RESULT IN PERSONAL INJURY OR DEATH.
  1. Perform Fuel Pressure Release Procedure. Refer to the FUEL PRESSURE RELEASE PROCEDURE  in this section.
  2. Disconnect negative cable from battery or auxiliary jumper terminal.
  3. Squeeze retainer tabs together and pull fuel tube/quick-connect fitting assembly off of fuel tube nipple. The retainer will remain on fuel tube.