Charging System: Generator: Removal: 5.7L
WARNING:
Disconnect negative cable from battery before removing battery output wire (B+ wire) from generator. Failure to do so can result in injury or damage to electrical system.
- Disconnect negative battery cable at battery.
- Remove generator drive belt. Refer to COOLING for procedure.
- Unsnap plastic insulator cap from B+ output terminal.
- Remove B+ terminal mounting nut at rear of generator. Disconnect terminal from generator.
- Disconnect field wire connector at rear of generator by pushing on connector tab.
- Remove generator support bracket nuts and bolt (3) and (4) and remove support bracket (2).
- Remove 2 generator mounting bolts (1) and (3).
- Remove generator (2) from vehicle.