Blower Switch Test

Disconnect blower switch harness. Using an ohmmeter, check continuity between switch terminals while operating switch. See Fig 1. If continuity is not as specified, replace switch. See BLOWER SWITCH CONTINUITY TEST table.

Fig 1: Identifying Blower Switch Terminals
G91D04778Courtesy of CHRYSLER MOTORS.
BLOWER SWITCH CONTINUITY TEST

Switch Position Terminals Continuity
Off - No
Low 5 & 3, 1 & 8 Yes
Medium Low 5 & 6, 1 & 8 Yes
Medium High 1 & 4, 1 & 8, 4 & 8, 5 & 7 Yes
High 1 & 4, 1 & 8, 4 & 8, 5 & 7 Yes