Main Switch
- When switch is moved to Neutral position, continuity should be present between terminals No. 4 and 6. See Figure . When switch is moved to ON position, continuity should be present between terminals No. 2, 4 and 6.
- Connect battery voltage to terminal No. 2 and ground terminal No. 6. Battery voltage should be present on terminal No. 4 when main switch is moved to ON position. Replace switch if it does not test correctly.