Door Switch Test
Remove switch from mounting location. Use an ohmmeter to check for correct continuity with switch in lock and unlock positions. If any continuity does not check as shown, replace switch. See DOOR LOCK SWITCH CONTINUITY . See Fig 1.
DOOR LOCK SWITCH CONTINUITY
| Switch Position | Terminals | Continuity |
|---|---|---|
| Open | 2 & 3 | Yes |
| Closed | 1 & 3 | Yes |
NOTE:
Terminal No. 1 is top left pin of switch connector, terminal No. 2 is top right pin and terminal No. 3 is bottom pin.