Module Programming: Calibration
multimedia:A supplement to the article is available.
NOTE:
The following procedure explains how to calibrate the Forward Facing Camera HALF (FFCM-HALF) when replacing the FFCM-HALF (a replacement FFCM-HALF is not factory calibrated). This procedure should also be used when the windshield is replaced.
Perform the following checks and setup prior to performing the calibration procedure:
- Confirm that the vehicle is unloaded (no luggage or extra weight being carried).
- Check and correct the tire pressures as needed.
- Check that the windshield is free of damage, is clean and that there are no impediments to the vision of the FFCM-HALF.
- Place the vehicle on level ground and in good light.
- Align the wheels to the longitudinal axis of the car.
CALIBRATION PROCEDURE
- Setup the (special tool #2076800080, ADAS Calibration System)
- Connect the diagnostic scan tool and start the vehicle. The system must not be activated.
- Navigate to the HALF and then select the Misc. Functions tab.
- Select and perform the Service Single Pole Calibration procedure.
- Follow the procedures instructions to complete the calibration procedure.
NOTE:
If during operation, the LDW+ system releases alerts inconsistent with the actual driving conditions (e.g. the vehicle properly between lanes but notice the crossing lane), the system must be calibrated again.