FixVault

Ground Circuit Continuity Check

  1. Carefully insert a small straight pin in ignition module Black wire. Attach negative voltmeter lead to ground. Attach positive voltmeter lead to straight pin.
  2. Turn ignition switch to "RUN" position, measure voltage. Turn ignition switch "OFF", remove straight pin.
  3. If voltage was more than 0.5 volt, proceed to "Wiring Harness Ground Circuit Check". If voltage was less than 0.5 volt, replace ignition module.