Removal & Installation: Introduction: Installation
Reverse removal procedure to install with following exceptions:
- When installing water inlet and discharge pipes, use a pipe sealant with Teflon D8AZ-19554-A or equivalent. Install inlet fitting within 5° of vertical, pointing down.
- Always use new gasket between turbocharger and mounting block.
- Use new nuts on turbocharger mounting studs.