FixVault

Solenoid Valve (SV) Check At ABS Control Module

  1. Turn ignition off. Disconnect ABS control module. Set VOM on 200 ohm scale.
  2. At ABS control module, measure and record resistance between following wires:
    • Green/Red wire and Black/White wire.
    • Green/Red wire and Blue wire.
    • Green/Red wire and Blue/Orange wire.
    • Green.
  3. If resistances are about 3 ohms, go to PINPOINT TESTS HSI-1  and HSI-2  . If resistances are not as specified, go to PINPOINT TEST SV-4  .