FixVault

Cylinder Id Sensors Test (2.2L Probe Turbo Only)

Disconnect distributor connector. Measure resistance between distributor connector terminals CID1 and CID REF. See Fig 1 . Resistance readings should be between 210-260 ohms. If sensor values are not within specifications, replace sensor(s).

Fig 1: 2.2L Probe Turbo Distributor Connector Terminal ID
G90I10171Courtesy of FORD MOTOR CO.