Isolating Compressor
NOTE:
For compressor application, see A/C SPECS In The AIR CONDITIONING and HEAT section.
NOTE:
Only compressors with stem-type service valves can be isolated.
- Connect manifold gauge set to compressor service valves. Ensure valves on gauge set are closed. Place both valves on compressor in the mid-position. Start engine and operate air conditioning.
- Slowly turn compressor suction valve clockwise toward closed (front-seated) position. When suction pressure is reduced to zero, turn engine and compressor off and quickly turn suction valve stem inward to the full front-seated position. Turn discharge valve into front-seated position.
- Loosen oil level plug to release internal pressure in the compressor. Compressor is now isolated from the rest of the system and service valves can be removed from the compressor.