FixVault

Rectifier Assembly Test

  1. Remove rectifier assembly from alternator. Set ohmmeter to X1 range. Connect one ohmmeter probe to "B+" terminal. Connect other ohmmeter probe to each of 3 stator lead terminals in turn. See Fig 1.
  2. Reverse probes and repeat test. All diodes should have resistance of approximately 7 ohms in one direction, and infinite resistance with probes reversed.
  3. Repeat test for negative set of diodes by connecting one ohmmeter probe to rectifier assembly base plate, and contacting each of 3 stator lead terminals with other ohmmeter probe. See Fig 1. If resistance is not as specified in step 2), replace rectifier assembly.
Fig 1: Testing Rectifier Assembly
G106368Courtesy of FORD MOTOR CO.