Instrument Ground Continuity Check
Turn ignition off. Remove instrument cluster. Measure resistance between 18-pin connector terminal No. 2R (Black/Blue wire) and ground. See IDENTIFYING VOLTMETER CIRCUIT illustration. If resistance is less than 5 ohms, replace instrument cluster. If resistance is at least 5 ohms, repair Black/Blue wire to ground.