FixVault

Output Gear: Reassembly

  1. Remove screws, washers, bearing housing, gauge and bearing cup. Press selected shim(s) and bearing cup into bearing housing using Bearing Installer (T60K-4616-A).
  2. Install bearing housing. Tighten retaining bolts to 14-19 ft. lbs. (19-26 N.m). Measure bearing preload. Preload should be .26-7.81 INCH lbs. (.03-.90 N.m). If preload is not within specification, repeat procedure. Remove bearing housing when proper preload specification is obtained.