Voltmeter Inoperative
- Check 15-amp instrument panel fuse in interior fuse block. Fuse panel is located just above left kick panel. If fuse is okay, see INSTRUMENT PANEL SUPPLY CHECK.
- If fuse is blown, replace fuse. If fuse blows again, check for short to ground in Black/Yellow wire at instrument panel 18-pin connector. Repair as necessary.
- If power and ground circuits to instrument cluster are okay, but voltmeter indicates incorrectly, replace instrument cluster.