Load Test

Connect battery/charging system tester to vehicle. With engine running at 2000 RPM, place a load on charging system. Amperage output should be within 10 percent of the generator's rated output of 60 amps. If generator output is as specified, generator is functioning properly. If generator output is not as specified, perform NO-LOAD TEST.