FixVault

Line Pressure High In All Ranges

Check main regulator valve, solenoid body and wiring harness and perform Quick Test procedure.

LINE PRESSURE SPECIFICATIONS (PSI)

Selector Position Idle RPM WOT Stall RPM
"P" & "N" 64-76 N/A
"R" 64-76 259-294
"D" 45-63 168-184
"2" 45-63 168-184
"L" 45-63 168-184
Fig 1: Identifying Line Pressure Test Port
G94A36616Courtesy of FORD MOTOR CO.