Line Pressure High In All Ranges

WARNING: This page is about a different variant/trim than selected.

Check main regulator valve, solenoid body and wiring harness and perform Quick Test procedure.

LINE PRESSURE SPECIFICATIONS (PSI)

Selector Position Idle RPM WOT Stall RPM
"P" & "N" 64-76 N/A
"R" 64-76 259-294
"D" 45-63 168-184
"2" 45-63 168-184
"L" 45-63 168-184
Fig 1: Identifying Line Pressure Test Port
G94A36616Courtesy of FORD MOTOR CO.