Engine Controls - Basic Testing
›
Idle Speed & Ignition Timing
›
Ignition Timing
Ignition Timing
BASE IGNITION TIMING
Application
Degrees BTDC @ Idle
2.0L (VIN 3)
(1)
(2)
8-12
(1)
Disconnect single in-line SPOUT connector, or remove shorting bar from double-wire SPOUT connector.
(2)
Timing is not adjustable.