FixVault

Power Door Lock Switch: Probe

  1. Remove door lock switch to be tested. With door lock switch in neutral position, no continuity should exist between Blue/Red wire and Green/Black wire at door lock cylinder switch. See WIRING DIAGRAMS .
  2. With switch in lock or unlock position, continuity should exist between Blue/Red wire and Green/Black wire at door lock switch. If continuity is not as specified, replace switch.