Symptom Chart
WARNING: This page is about a different car, the 2005 Ford RV Cutaway, 2005 Ford Econoline, 2005 Ford E450 Super Duty, and 2005 Ford Cutaway. However, it is still accessible from the selected car via links, so may be relevant.
WARNING DEVICES SYMPTOM CHART
| Condition |
Possible Sources |
Action |
- All the chimes are inoperative
|
|
- MONITOR the warning lamps. If the warnings lamps do not operate correctly, REFER to INSTRUMENT CLUSTER
to continue diagnosis of the instrument cluster.
|
- The safety belt warning chime does not operate correctly (warning indicator operates properly)
|
- Circuitry
- Safety belt switch
- Instrument cluster
|
|
- The key-in-ignition chime does not operate correctly
|
- Circuitry
- Key-in-ignition switch
- Instrument cluster
- Courtesy lamp switch
|
|
- The headlamp on reminder chime does not operate correctly
|
- Circuitry
- Instrument cluster
- Courtesy lamp switch
- Headlamp switch
|
|
- The air bag chime does not operate correctly
|
- Restraint control module (RCM)
- Instrument cluster
|
- CHECK the operation of the safety belt and air bag warning indicators.
- If the safety belt and air bag warning indicators operate correctly, INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER
.
- If the safety belt and air bag warning indicators do not operate correctly, REFER to INSTRUMENT CLUSTER
to continue diagnosis of the warning indicators.
|
- The park brake warning chime does not operate correctly
|
- Parking brake switch
- Instrument cluster
|
- CHECK the operation of the brake warning indicator.
- If the brake warning indicator operates correctly, INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER
.
TEST the system for normal operation.
- If the brake warning indicator does not operate correctly, REFER to INSTRUMENT CLUSTER
to continue diagnosis of the brake warning indicator.
|
- The fail safe cooling warning chime is inoperative (the temperature gauge is in the HOT range and the CHECK GAGE indicator flashes)
|
|
- INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER
.
TEST the system for normal operation.
|