FixVault

Refrigerant System Tests

WARNING: This page is about a different car, the 2003 Ford Focus. However, it is still accessible from the selected car via links, so may be relevant.
  1. Connect an A/C recovery and/or charging station with gauges, or Connect an R134a manifold gauge set to the refrigerant system.
  2. Set the climate control system to MAX A/C (if equipped), or select A/C and RECIRC (if equipped), at HI blower.
  3. NOTE: When the ambient temperature exceeds 38°C (100°F), do not run the engine above normal idle speed.
  4. Run the engine at 1500 rpm for 10 minutes.
  5. Stabilize the vehicle interior temperature at 21°C to 27°C (70°F to 80°F).
  6. Record the high and low system pressures using the R134a Manifold Gauge Set, and refer to Fig 1 and/or Fig 2 .
Fig 1: Refrigerant System Diagnostic Chart (1 Of 2)
G01614169Courtesy of FORD MOTOR CO.
Fig 2: Refrigerant System Diagnostic Chart (2 Of 2)
G01614170Courtesy of FORD MOTOR CO.