Preliminary Inspection
Verify customer concern by operating Remote Keyless Entry (RKE) system. Before performing any testing, perform a visual inspection. Check for obvious signs of mechanical and electrical damage. Check Battery Junction Box (BJB) fuse No. 16 (15-amp). BJB is located in left front of engine compartment, on top of wheelwell. Check Central Junction Box (CJB) fuses No. 3 (15-amp), No. 4 (15-amp) and No. 5 (20-amp). CJB is located under left side of instrument panel. See Figure. Check connectors for loose, damaged or corroded terminals. Check for damaged wiring harness or switches. Check for damaged power door lock actuator. Check for low remote transmitter battery charge or damaged transmitter. Check RKE module. RKE module is located behind left quarter trim panel ("B" pillar). Repair as necessary. If no problem is found, repair by symptom. See SYMPTOM INDEX table under SYSTEM TESTS.