ABS control module Connector End View (C840)

Fig 1: Identifying ABS Control Module Connector (C840)
G10361540Courtesy of FORD MOTOR CO.
Pin Circuit Circuit Function
1 30-CF13A (RD) Voltage supplied at all times (not overload protected)
2 8-EE6A (WH) Sensor signal
3 8-CE8 (WH/BU) Sensor signal
4 15-CF6A (GN/YE) Voltage, ignition switch in Start or Run (not overload protected)
5 9-CF1 (BN/RD) Sensor signal return (reference/ground)
6 10-CE8 (GY/VT) Sensor signal
7 7-CF1 (YE/RD) Voltage DC. supplied at all times (sensor)
8 - not used
9 - not used
10 - not used
11 - not used
12 - not used
13 31S-CF45A (BK/GN) Ground, switched
14 - not used
15 - not used
16 91-CF6 (BK/YE) Ground
17 - not used
18 7-CF64 (YE/BK) Voltage DC. supplied at all times (sensor)
19 9-CF64 (BN/YE) Sensor signal return (reference/ground)
20 8-CF64 (WH/BK) Sensor signal
21 - not used
22 - not used
23 - not used
24 - not used
25 5-EC12 (BU/RD) Data link, bus negative
26 - not used
27 - not used
28 - not used
29 4-EC12 (GY/RD) Data link, bus positive
30 - not used
31 - not used
32 30-CF6A (RD)  
33 9-CF38 (BN/RD) Sensor signal return (reference/ground)
34 8-CF38 (WH/RD) Sensor signal
35 - not used
36 8-CF34 (WH/BU) Sensor signal