FixVault

Inline Connector End View (C320)

Fig 1: Identifying Inline Connector (C320)
G10361420Courtesy of FORD MOTOR CO.
Pin Circuit Circuit Function
1 64-LE1 (BU) Variable D.C. voltage (not overload protected)
2 15S-LD6 (GN/YE) Voltage, ignition switch in Start or Run (not overload protected), switched
3 15S-LD9 (GN/BK) Voltage, ignition switch in Start or Run (not overload protected), switched
15S-LD1 (GN/YE) Voltage, ignition switch in Start or Run (not overload protected), switched
4 15S-LE6 (GN/YE) Voltage, ignition switch in Start or Run (not overload protected), switched
15S-LE14 (GN/RD) Voltage, ignition switch in Start or Run (not, switched
5 - not used
6 15S-LE14 (GN/RD) Voltage, ignition switch in Start or Run (not overload protected), switched
15S-LE14B + (GN/RD) Voltage, ignition switch in Start or Run (not overload protected), switched
15S-LE19 (GN/BU) Voltage, ignition switch in Start or Run (not overload protected), switched
7 15-LD16 (GN/RD) Voltage, ignition switch in Start or Run (not overload protected), switched
8 15-LE29 (GN/BK) Voltage, ignition switch in Start or Run (not overload protected)
9 29S-DA2 (OG/BU) Voltage supplied at all times (overload protected), switched
10 31-LE29 (BK) Ground
11 29-LE29 (OG/BK) Voltage supplied at all times (overload protected)
12 30S-LE29 (RD/GN) Voltage supplied at all times (not overload protected), switched
30S-LE29A (RD/GN) Voltage supplied at all times (not overload protected), switched
13 29S-LF1 (OG/YE) Voltage supplied at all times (overload protected), switched
14 - not used
15 15S-LE29 (GN/BK) Voltage, ignition switch in Start or Run (not overload protected), switched
16 29S-LF21 (OG/BK) Voltage supplied at all times (overload protected), switched
29S-LF5 (OG/BU) Voltage supplied at all times (overload protected), switched
29S-LE18 (OG/YE) Voltage supplied at all times (overload protected), switched