FixVault

Digital Transmission Range (TR) Sensor: Installation

WARNING: This page is about a different car, the 2002 Ford Windstar. However, it is still accessible from the selected car via links, so may be relevant.
  1. Verify that the transaxle range selector lever is in NEUTRAL.
  2. Install the digital TR sensor and loosely install the bolts.
    Fig 1: Installing Digital TR Sensor
    G02144674Courtesy of FORD MOTOR CO.
  3. Using the special tool, align the digital TR sensor.
    Fig 2: Aligning Digital TR Sensor
    G02144675Courtesy of FORD MOTOR CO.
  4. Install the manual control lever and nut.
    Fig 3: Installing Manual Control Lever And Nut
    G02144676Courtesy of FORD MOTOR CO.
  5. Connect the shift cable.
    Fig 4: Connecting Shift Cable
    G02144677Courtesy of FORD MOTOR CO.
  6. Verify that the shift cable is correctly adjusted. For additional information, refer to TRANSAXLE/TRANSMISSION EXTERNAL CONTROLS .
  7. Connect the digital TR range sensor electrical connector.
    Fig 5: Connecting Digital TR Range Sensor Electrical Connector
    G02144678Courtesy of FORD MOTOR CO.
  8. Install the engine air cleaner assembly. For additional information, refer to AIR INDUCTION SYSTEMS .
  9. Check for correct vehicle operation.