FixVault

Disassembly & Assembly

  1. If equipped, remove the drain plug and drain the fluid from the torque converter.
    Fig 1: Removing Drain Plug And Drain Fluid From Torque Converter
    G01273750Courtesy of FORD MOTOR CO.
  2. Install fluid pump support into the torque converter. Engage splines of the one-way clutch inner race with the mating splines of the overdrive pump support.
    Fig 2: Installing Fluid Pump Support Into Torque Converter
    G01273751Courtesy of FORD MOTOR CO.
  3. While holding the fluid pump support stationary, rotate the torque converter clockwise and counterclockwise. The torque converter should rotate freely with no signs of scraping. If there are signs of scraping, install a new or remanufactured torque converter.
    Fig 3: Rotating Torque Converter Clockwise And Counterclockwise
    G01273752Courtesy of FORD MOTOR CO.
  4. If equipped, install a new drain plug in the torque converter.
    Fig 4: Installing Drain Plug In Torque Converter
    G01273753Courtesy of FORD MOTOR CO.