FixVault

Removal and Installation

  1. Remove the integrated control panel. For additional information, refer to CLIMATE CONTROL ASSEMBLY  .
  2. Remove the right-side lower instrument panel insulator.
    Fig 1: Locating Right-Side Lower Instrument Panel Insulator
    G01595046Courtesy of FORD MOTOR CO.
  3. Open the glove compartment. Pressing the tabs inward, lower the glove compartment towards the floor.
    Fig 2: Pressing Tabs Inward, Lower Glove Compartment Towards Floor
    G01595047Courtesy of FORD MOTOR CO.
  4. Remove the screw.
    Fig 3: Locating Screw
    G01595048Courtesy of FORD MOTOR CO.
  5. Remove the screw.
    Fig 4: Removing Screw
    G01595049Courtesy of FORD MOTOR CO.
  6. Disconnect the remote climate control (RCC) module electrical connector.
    Fig 5: Locating Remote Climate Control (RCC) Module Electrical Connector
    G01595050Courtesy of FORD MOTOR CO.
  7. Remove the two nuts. Disconnect the plenum vacuum harness. Remove the RCC module (18C612).
    Fig 6: Locating Plenum Vacuum Harness
    G01595051Courtesy of FORD MOTOR CO.
  8. To install, reverse the removal procedure.