FixVault

Generator Specifications

WARNING: This page is about a different car, the 2003 Ford Windstar and 2002 Ford Windstar. However, it is still accessible from the selected car via links, so may be relevant.
GENERATOR SPECIFICATIONS

Application Specification
Generator Amperage Rating 135 Amps
Generator Pulley Ratio (Generator Pulley Revolutions: Engine Revolutions) 2.67:1
Load Test (1)
With Tester Load (2) (3)
Without Tester Load (4) (5)
No-Load Test (1)(2) 13-15 Volts
(1) All tests are performed with engine running at 2000 RPM.
(2) All accessories off.
(3) Adjust tester load bank to determine generator output.
(4) Perform this test with engine running, A/C on, blower motor on high speed, and headlamps on high beam.
(5) With accessories on, voltage should increase a minimum of 0.5 volt above base voltage.