MASTER WINDOW ADJUST SWITCH - COMPONENT TESTING

Circuit to test Connect self-powered test light or ohmmeter to terminals Move switch to these positions A good switch will indicate
Power and Ground Checks Before Any Other Tests 3 and 2, 3 and 8, 3 and 4, 3 and 10, 1 and 7, 1 and 9 All window switches at rest Open circuit
Left front window circuit 3 and 8, 1 and 7 Up Closed circuit
3 and 2, 1 and 7 Down Closed circuit
Right front window circuit 3 and 10, 1 and 9 Up Closed circuit
3 and 4, 1 and 9 Down Closed circuit