FixVault

Fuel Pump Control Module: Removal

  1. Remove the Right Hand (RH) C-pillar trim panel REFER to C-PILLAR TRIM PANEL - WITH INFLATABLE SAFETY BELTS or REFER to C-PILLAR TRIM PANEL - WITHOUT INFLATABLE SAFETY BELTS .
  2. Disconnect the Fuel Pump (FP) control module electrical connector.
  3. Remove the 2 Fuel Pump (FP) control module retaining nuts.
  4. Remove the Fuel Pump (FP) control module.