FixVault

General Procedure

NOTE: Refer to general specifications in the appropriate 303-01 engine section for the appropriate specification.

Using the Feeler Gauge Set, measure the connecting rod bend on a suitable alignment fixture. Follow the instructions of the fixture manufacturer. Verify the bend measurement is within specification.

Fig 1: Measuring Connecting Rod Bend On Suitable Alignment Fixture
G07420852Courtesy of FORD MOTOR CO.