Initialization procedure
WARNING:
Keep objects and body parts clear of the glass panel when carrying out the initialization procedure. During the initialization procedure, the glass panel closes with high force and cannot detect objects in its path. Failure to follow this instruction may result in serious personal injury.
NOTE:
The window must be in the full OPEN position for this procedure to operate correctly.
NOTE:
If the initialization procedure is only partially completed, the window motor will remain de-initialized and will not operate in one-touch up mode.
- 5. Turn the ignition key ON.
- 6. Activate and hold the window control switch in the UP position at the second detent until the window glass stalls for 2 seconds into the glass top run and release the switch.
- 7. Activate and hold the window control switch in the DOWN position at the second detent until the window glass stalls for 2 seconds at the bottom of its travel and release the switch.
- 8. Test for correct window operation by carrying out the one-touch up and one-touch down features.